Novatek Novair 1000 Negative Air Machine – F1005, 1000 CFM, Standard Filter

Novatek Novair 1000 Negative Air Machine – F1005, 1000 CFM, Standard Filter
Su información de pago se procesa de forma segura. No almacenamos los datos de su tarjeta de crédito ni tenemos acceso a ella.
Generalmente se envía en un plazo de 3 a 5 días y se entrega en un plazo de 10 días hábiles.
General-Purpose 1000 CFM Negative Air Machine for Construction and Renovation
The Novatek Novair 1000 (F1005) delivers the same 1 HP, 1000/500 CFM two-speed platform as the HEPA model but configured with a general-purpose dust filter, 1/2" pad, and ring filter for non-hazardous particulate control. It draws 5 amps at 115V, weighs 91 lbs (lighter than the HEPA version due to different filter pack), and uses the integrated hand-truck frame for one-person transport.
F1005 Motor, Filter Configuration & Power Requirements
- 1000 CFM high / 500 CFM low — true airflow with filters installed, independently tested.
- General-purpose dust filter + 1/2" pad + ring filter — captures construction dust, drywall, and nuisance particulate without HEPA pricing.
- Upgradeable to HEPA — the housing accepts a standard 16" x 16" x 11.5" HEPA filter when hazardous material exposure is identified mid-project.
- 5-amp draw at 115V — standard circuit compatible; no dedicated wiring required.
- 91 lbs with integrated hand-truck wheels and skids — lighter than the HEPA version, single-operator transport.
- Compact 20" x 23" footprint — fits through standard doorways and into tight spaces.
- Durable polyethylene housing — dent-proof and leak-resistant for job-site conditions.
Construction and Facility Applications
General contractors use the F1005 for construction dust control during occupied building renovations where HEPA is not required by regulation. Healthcare facilities deploy it in mechanical rooms and maintenance corridors during HVAC and plumbing work to prevent dust migration into patient areas. Restoration contractors use it as a preliminary dust control unit before confirmatory testing determines whether hazardous materials are present and a HEPA upgrade is needed. Schools and office buildings benefit from it during tenant improvement work in occupied environments where disruption must be minimized.
Certifications & What Ships in the Box
The F1005 ships with general-purpose dust filter, 1/2" pad, and ring filter installed. Xactimate code for non-hazardous air filtration: AQRS. Unit weight: 91 lbs.
| Model / Part Number | F1005 |
|---|---|
| Weight | 91 lbs / 41 kg |
| Dimensions (W × D × H) | 20″ × 23″ × 40″ |
| Motor | 1 HP – Two Speed, Thermally Protected |
| Air Volume (High/Low) | 1000 / 500 CFM |
| Power Requirements | 115V, 5A, 60 Hz |
| Filtration | Dust Filter, 1/2″ Pad, Ring Filter |